
ACT-457A Panel PC
Page 28
CAUTION:
1. Digital input
A. The system includes a digital input power source
B. Digital input must be less than 50 VDC
2. Relay output
A. Do not exceed maximum contact capacity, limits listed below
240 VAC @ 10 A
120 VAC @ 12 A
28 VDC @ 10 A
B. Total current consumed by peripherals must be < 1 A
C. Relay signal can affect digital input signal, space cables apart
D. Do not connect peripherals with unknown specifications
E. Do not connect unrated/untested external power supplies
The digital I/O port connects to door sensors and alarms. To connect the wires from the
sensor or alarm to the ACT-457A, follow the directions below.
Step 1: Strip 5 mm of cable housing from the end of the cable.
Step 2: Loosen the screw.
Step 3: Position the cable.
Step 4: Tighten the screw to hold the cable in place. Step 0:
Comentários a estes Manuais