RPC-6022GW Rackmount LCD Workstation
Page 69
Step 6:
Step 7:
Step 8:
Step 9:
Step 10:
Remove the two internal retention screws that secure the PSU assembly to the
right side panel of the workstation (Figure 5-2).
Figure 5-2: PSU Internal Retention Screws
Install the new PSU into the workstation making sure the PSU power connector
and PSU cooling fan are facing out of the workstation.
Reinsert the two previously removed internal retention screws that secure the
PSU assembly to the right side panel of the workstation.
Reinsert the four previously removed external retention screws that secure the
PSU assembly to the rear panel of the workstation.
Close the back cover of the workstation and reinstall the workstation into the
cabinet or rack in which it was previously installed. Refer to Section 4.6 for
complete mounting instructions. Step 0: