Iei-integration AFL-W19A_W19B_17D_W15A-GM45 v1.06 Manual do Utilizador Página 53

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 138
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes
Vista de página 52
AFL-W19A/W19B/17D/W15A-GM45 Panel PC
Page 41
Î
Automatic mode
The fan adjusts its speed using these settings:
Temp. Limit of OFF
Temp. Limit of Start
Fan Start PWM
Slope PWM 1
Î
PWM Manual mode
The fan spins at the speed set in:
Fan PWM control
Î Temp. Limit of OFF [000]
WARNING:
CPU failure can result if this value is set too high
The fan will turn off if the temperature falls below this value.
Minimum Value: 0°C
Maximum Value: 127°C
Î Temp. Limit of Start [020]
WARNING:
CPU failure can result if this value is set too high
When the fan is off, it will only start when the temperature exceeds this setting.
Minimum Value: 0°C
Maximum Value: 127°C
Î Start PWM [070]
This is the initial speed of the fan when it first starts spinning.
PWM Minimum Mode: 0
Vista de página 52
1 2 ... 48 49 50 51 52 53 54 55 56 57 58 ... 137 138

Comentários a estes Manuais

Sem comentários