Page 134
A.1.2 CPU Temperature Warning
WARNING:
If the CPU Temperature Alert LED shows RED, the CPU core
temperature is too high. To lower the CPU temperature, lower the
environment temperature or decrease the amount of running programs.
A.1.3 Anti-static Precautions
WARNING:
Failure to take ESD precautions during the installation of the
AFL2-W10A-N28 may result in permanent damage to the
AFL2-W10A-N28 and severe injury to the user.
Electrostatic discharge (ESD) can cause serious damage to electronic components,
including the AFL2-W10A-N28. Dry climates are especially susceptible to ESD. It is
therefore critical that whenever the AFL2-W10A-N28 is opened and any of the electrical
components are handled, the following anti-static precautions are strictly adhered to.
Wear an anti-static wristband: Wearing a simple anti-static wristband can
help to prevent ESD from damaging any electrical component.
Self-grounding: Before handling any electrical component, touch any
grounded conducting material. During the time the electrical component is
handled, frequently touch any conducting materials that are connected to the
ground.
Use an anti-static pad: When configuring or working with an electrical
component, place it on an antic-static pad. This reduces the possibility of ESD
damage.
Only handle the edges of the electrical component: When handling the
electrical component, hold the electrical component by its edges.